STOMP

Output Control Card Examples (HYDT-KE)

2 ref. nodes + 16 ref. node variables + + No Plot Times + 15 plot file variables
~Output Control Card
2,
1,1,1,
2,1,1,
1,1,s,m,6,6,6,
16,
Phase Condition,,
Gas Pressure,MPa,
Aqueous Pressure,MPa,
Gas CO2 Mole Fraction of Formers,,
Gas CH4 Mole Fraction of Formers,,
Gas N2 Mole Fraction of Formers,,
Temperature,c,
Aqueous Saturation,,
Gas Saturation,,
Hydrate Saturation,,
Hydrate CO2 Mass Fraction,,
Hydrate CH4 Mass Fraction,,
Hydrate N2 Mass Fraction,,
CO2 Gas Mass Fraction,,
CH4 Gas Mass Fraction,,
Integrated CO2 Mass,kg,
0,
15,
Gas Pressure,MPa,
Aqueous Pressure,MPa,
Temperature,c,
Aqueous Saturation,,
Nonaqueous Liquid Saturation,,
Gas Saturation,,
Hydrate Saturation,,
Hydrate CO2 Mass Fraction,,
Hydrate CH4 Mass Fraction,,
CO2 Aqueous Mass Fraction,,
CH4 Aqueous Mass Fraction,,
CO2 Nonaqueous Liquid Mass Fraction,,
CH4 Nonaqueous Liquid Mass Fraction,,
CO2 Gas Mass Fraction,,
CH4 Gas Mass Fraction,,
11 ref. nodes + 16 ref. node variables + No Plot Times + 12 plot file variables
~Output Control Card
11,
1,1,1,
1,1,10,
1,1,20,
1,1,30,
1,1,40,
3.7 6
1,1,50,
1,1,60,
1,1,70,
1,1,80,
1,1,90,
1,1,100,
1,1,s,cm,6,6,6,
16,
Temperature,C,
Gas Pressure,MPa,
Aqueous Pressure,MPa,
Aqueous Density,kg/m^3,
Gas Density,kg/m^3,
Hydrate Density,kg/m^3,
CH4 Aqueous Mass Fraction,,
CH4 Gas Mass Fraction,,
CH4 Hydrate Mass Fraction,,
Aqueous Saturation,,
Gas Saturation,,
Hydrate Saturation,,
Integrated CH4 Mass,gm,
Integrated H2O Mass,gm,
Integrated Hydrate CH4 Mass,gm,
Integrated Hydrate H2O Mass,gm,
0,
12,
Temperature,C,
Gas Pressure,MPa,
Aqueous Pressure,MPa,
Aqueous Density,kg/m^3,
Gas Density,kg/m^3,
Hydrate Density,kg/m^3,
CH4 Aqueous Mass Fraction,,
CH4 Gas Mass Fraction,,
CH4 Hydrate Mass Fraction,,
Aqueous Saturation,,
Gas Saturation,,
Hydrate Saturation,,

STOMP User Guide Home