STOMP

Hydraulic Properties Card Syntax (HYDT-KE)

Input Data Types

Character string (e.g., van Genuchten, porosity, m^3/s, Roe Superbee)

Integer (no alpha characters, special characters, or punctuation) (e.g., 1, 32, 195634)

Real (decimal points and exponential notation allowed) (e.g., 0, 0.0, 1.e-12, 1.E+3, 2.345)

Keyword (exact formatting required) (e.g., file, ~Solution Control Card, binary file)

Card Title

~Hydraulic Properties Card,

 Rock/Soil or Scaling Group Name, Hydraulic Property

Repeat

Repeat for each rock/soil type

Info

IJK, JKI, or KIJ Indexing

Expand for Syntax

If Rock/Soil Name is IJK Indexing, JKI Indexing, or KIJ Indexing then a parameter value can replaced with an external file using the following formatting for ASCII files:

...,file:file name,...

or binary files:

...,binary file:file name,...
The external file will contain parameter values for every grid-cell ordered according to the indexing scheme (i.e., IJK, JKI, or KIJ). Units shown in the input line will be applied to all parameters in the external file.

Rock/Soil Name, Hydraulic Property

Choose One

Choose one hydraulic property type

Intrinsic Permeability

Rock/Soil Name,X-Direction Intrinsic Permeability,Units (m^2),Y-Direction Intrinsic Permeability,Units (m^2),Z-Direction Intrinsic Permeability,Units (m^2), Civan Beta Parameter(Optional),

Hydraulic Conductivity

Rock/Soil Name,X-Direction Hydraulic Conductivity,hc Units (m^2),Y-Direction Hydraulic Conductivity,hc Units (m^2),Z-Direction Hydraulic Conductivity,hc Units (m^2),Civan Beta Parameter(Optional),

Info

Cylindrical Coordinate System

If a cylindrical coordinate system is specified, the the X-direction is the Radial direction and the Y-direction is the Azimuthal direction.

 

 

STOMP User Guide Home