STOMP

Solute/Fluid Interaction Card Syntax (GT)

Input Data Types

Character string (e.g., van Genuchten, porosity, m^3/s, Roe Superbee)

Integer (no alpha characters, special characters, or punctuation) (e.g., 1, 32, 195634)

Real (decimal points and exponential notation allowed) (e.g., 0, 0.0, 1.e-12, 1.E+3, 2.345)

Keyword (exact formatting required) (e.g., file, ~Solution Control Card, binary file)

Card Title

~Solute/Fluid Interactions Card

Number of Solutes

Number of Solutes,

Choose One

Choose one effective diffusion option

Constant
Choose One

Choose one solute partition option

Continuous
Choose One

Choose one reaction option

No Reaction
Repeat

Repeat for number of solutes

Solute Name,Constant,Aqueous-Phase Molecular Diffusion Coefficient @ 20o C, Units(m2/s), Continuous,

Radioactive Decay
Choose One

Choose one based on option selected in Solution Control Card

Aqueous-Only Courant Number Control
Repeat

Repeat for number of solutes

Solute Name,Constant,Aqueous-Phase Molecular Diffusion Coefficient @ 20o C, Units(m2/s), Continuous, Half-life, Units(s), Aqueous-Phase Cutoff Concentration, Units(1/L3),

Number of Chain Decay Input Lines,

Repeat

Repeat for number of chain decay lines

Parent Solute Name, Progeny Solute Name, Chain Decay Fraction

All Other Options
Repeat

Repeat for number of solutes

Solute Name,Constant,Aqueous-Phase Molecular Diffusion Coefficient @ 20o C, Units(m2/s), Continuous, Half-life, Units(s),

Number of Chain Decay Input Lines,

Repeat

Repeat for number of chain decay lines

Parent Solute Name, Progeny Solute Name, Chain Decay Fraction

Warning

This option requires the Radioactive Decay Module to be implemented in the simulator.

First-Order Reactions
Repeat

Repeat for number of solutes

Solute Name,Constant,Aqueous-Phase Molecular Diffusion Coefficient @ 20o C, Units(m2/s), Continuous, Number of Reactions, ...

Repeat

Repeat for number of reactions

...First-order Reaction Rate Constant, Units(s),

Number of Reaction Input Lines,

Repeat

Repeat for number of reaction lines

Parent Solute Name, Daughter Solute Name, Reaction NumberReaction Stoichiometry Fraction

Warning

This option requires the Reactions Module to be implemented in the simulator.

Noncontinuous
Choose One

Choose one reaction option

No Reaction
Repeat

Repeat for number of solutes

Solute Name,Constant,Aqueous-Phase Molecular Diffusion Coefficient @ 20o C, Units(m2/s), Noncontinuous,

Radioactive Decay
Choose One

Choose one based on option selected in Solution Control Card

Aqueous-Only Courant Number Control
Repeat

Repeat for number of solutes

Solute Name,Constant,Aqueous-Phase Molecular Diffusion Coefficient @ 20o C, Units(m2/s), Noncontinuous, Half-life, Units(s), Aqueous-Phase Cutoff Concentration, Units(1/L3),

Number of Chain Decay Input Lines,

Repeat

Repeat for number of chain decay lines

Parent Solute Name, Progeny Solute Name, Chain Decay Fraction
All Other Options
Repeat

Repeat for number of solutes

Solute Name,Constant,Aqueous-Phase Molecular Diffusion Coefficient @ 20o C, Units(m2/s), Noncontinuous, Half-life, Units(s),

Number of Chain Decay Input Lines,

Repeat

Repeat for number of chain decay lines

Parent Solute Name, Progeny Solute Name, Chain Decay Fraction
Warning

This option requires the Radioactive Decay Module to be implemented in the simulator.

First-Order Reactions
Repeat

Repeat for number of solutes

Solute Name,Constant,Aqueous-Phase Molecular Diffusion Coefficient @ 20o C, Units(m2/s), Noncontinuous, Number of Reactions, ...

Repeat

Repeat for number of reactions

...First-order Reaction Rate Constant, Units(s),

Number of Reaction Input Lines,

Repeat

Repeat for number of reaction lines

Parent Solute Name, Daughter Solute Name, Reaction Number, Reaction Stoichiometry Fraction
Warning

This option requires the Reactions Module to be implemented in the simulator.

Conventional
Choose One

Choose one solute partition option

Continuous
Choose One

Choose one reaction option

No Reaction
Repeat

Repeat for number of solutes

Solute Name,Conventional,Aqueous-Phase Molecular Diffusion Coefficient @ 20o C, Units(m2/s), Continuous,

Radioactive Decay
Choose One

Choose one based on option selected in Solution Control Card

Aqueous-Only Courant Number Control
Repeat

Repeat for number of solutes

Solute Name,Conventional,Aqueous-Phase Molecular Diffusion Coefficient @ 20o C, Units(m2/s), Continuous, Half-life, Units(s), Aqueous-Phase Cutoff Concentration, Units(1/L3),

Number of Chain Decay Input Lines,

Repeat

Repeat for number of chain decay lines

Parent Solute Name, Progeny Solute Name, Chain Decay Fraction
All Other Options
Repeat

Repeat for number of solutes

Solute Name,Conventional,Aqueous-Phase Molecular Diffusion Coefficient @ 20o C, Units(m2/s), Continuous, Half-life, Units(s),

Number of Chain Decay Input Lines,

Repeat

Repeat for number of chain decay lines

Parent Solute Name, Progeny Solute Name, Chain Decay Fraction
Warning

This option requires the Radioactive Decay Module to be implemented in the simulator.

First-Order Reactions
Repeat

Repeat for number of solutes

Solute Name,Conventional,Aqueous-Phase Molecular Diffusion Coefficient @ 20o C, Units(m2/s), Continuous, Number of Reactions, ...

Repeat

Repeat for number of reactions

...First-order Reaction Rate Constant, Units(s),

Number of Reaction Input Lines,

Repeat

Repeat for number of reaction lines

Parent Solute Name, Daughter Solute Name, Reaction Number, Reaction Stoichiometry Fraction
Warning

This option requires the Reactions Module to be implemented in the simulator.

Noncontinuous
Choose One

Choose one reaction option

No Reaction
Repeat

Repeat for number of solutes

Solute Name,Conventional,Aqueous-Phase Molecular Diffusion Coefficient @ 20o C, Units(m2/s), Noncontinuous,

Radioactive Decay
Choose One

Choose one based on option selected in Solution Control Card

Aqueous-Only Courant Number Control
Repeat

Repeat for number of solutes

Solute Name,Conventional,Aqueous-Phase Molecular Diffusion Coefficient @ 20o C, Units(m2/s), Noncontinuous, Half-life, Units(s), Aqueous-Phase Cutoff Concentration, Units(1/L3),

Number of Chain Decay Input Lines,

Repeat

Repeat for number of chain decay lines

Parent Solute Name, Progeny Solute Name, Chain Decay Fraction
All Other Options
Repeat

Repeat for number of solutes

Solute Name,Conventional,Aqueous-Phase Molecular Diffusion Coefficient @ 20o C, Units(m2/s), Noncontinuous, Half-life, Units (s),

Number of Chain Decay Input Lines,

Repeat

Repeat for number of chain decay lines

Parent Solute Name, Progeny Solute Name, Chain Decay Fraction
Warning

This option requires the Radioactive Decay Module to be implemented in the simulator.

First-Order Reactions
Repeat

Repeat for number of solutes

Solute Name,Conventional,Aqueous-Phase Molecular Diffusion Coefficient @ 20o C, Units(m2/s), Noncontinuous, Number of Reactions, ...

Repeat

Repeat for number of reactions

...First-order Reaction Rate Constant, Units(s),

Number of Reaction Input Lines,

Repeat

Repeat for each reaction line

Parent Solute Name, Daughter Solute Name, Reaction Number, Reaction Stoichiometry Fraction
Warning

This option requires the Reactions Module to be implemented in the simulator.

Empirical [Kemper and van Schaik]
Info

Model Parameters for the Empirical Option are entered in the Solute/Porous Media Interaction Card

Choose One

Choose one solute partition option

Continuous
Choose One

Choose one reaction option

No Reaction
Repeat

Repeat for number of solutes

Solute Name,Empirical, Continuous,

Radioactive Decay
Choose One

Choose one based on option selected in Solution Control Card

Aqueous-Only Courant Number Control
Repeat

Repeat for each solute

Solute Name,Empirical, Continuous, Half-life, Units(s), Aqueous-Phase Cutoff Concentration, Units(1/L3),

Number of Chain Decay Input Lines,

Repeat

Repeat for each decay line

Parent Solute Name, Progeny Solute Name, Chain Decay Fraction
All Other Options
Repeat

Repeat for number of solutes

Solute Name,Empirical, Continuous, Half-life, Units(s),

Number of Chain Decay Input Lines,

Repeat

Repeat for number of chain decay lines

Parent Solute Name, Progeny Solute Name, Chain Decay Fraction
Warning

This option requires the Radioactive Decay Module to be implemented in the simulator.

First-Order Reactions
Repeat

Repeat for number of solutes

Solute Name,Empirical, Continuous, Number of Reactions, ...

Repeat

Repeat for number of reactions

...First-order Reaction Rate Constant, Units(s),

Number of Reaction Input Lines,

Repeat

Repeat for number of reaction lines

Parent Solute Name, Daughter Solute Name, Reaction Number, Reaction Stoichiometry Fraction
Warning

This option requires the Reactions Module to be implemented in the simulator.

Noncontinuous
Choose One

Choose one reaction option

No Reaction
Repeat

Repeat for number of solutes

Solute Name,Empirical, Noncontinuous,

Radioactive Decay
Choose One

Choose one based on option selected in Solution Control Card

Aqueous-Only Courant Number Control
Repeat

Repeat for number of solutes

Solute Name,Empirical, Noncontinuous, Half-life, Units(s), Aqueous-Phase Cutoff Concentration, Units(1/L3),

Number of Chain Decay Input Lines,

Repeat

Repeat for number of chain decay lines

Parent Solute Name, Progeny Solute Name, Chain Decay Fraction
All Other Options
Repeat

Repeat for number of solutes

Solute Name, Empirical, Noncontinuous, Half-life, Units(s),

Number of Chain Decay Input Lines,

Repeat

Repeat for number of chain decay lines

Parent Solute Name, Progeny Solute Name, Chain Decay Fraction
Warning

This option requires the Radioactive Decay Module to be implemented in the simulator.

First Order Reactions
Repeat

Repeat for number of solutes

Solute Name, Empirical, Noncontinuous, Number of Reactions, ...

Repeat

Repeat for number of reactions

...First-order Reaction Rate Constant, Units(s),

Number of Reaction Input Lines,

Repeat

Repeat for number of reaction lines

Parent Solute Name, Daughter Solute Name, Reaction Number, Reaction Stoichiometry Fraction
Warning

This option requires the Reactions Module to be implemented in the simulator.

Choose One

Choose one solute partition option

Continuous
Choose One

Choose one reaction option

No Reaction
Repeat

Repeat for number of solutes

Solute Name, Power, Continuous,

Radioactive Decay
Choose One

Choose one based on option selected in Solution Control Card

Aqueous-Only Courant Number Control
Repeat

Repeat for number of solutes

Solute Name,Power, Continuous, Half-life, Units(s), Aqueous-Phase Cutoff Concentration, Units(1/L3),

Number of Chain Decay Input Lines,

Repeat

Repeat for number of chain decay lines

Parent Solute Name, Progeny Solute Name, Chain Decay Fraction
All Other Options
Repeat

Repeat for number of solutes

Solute Name,Power, Continuous, Half-life, Units(s),

Number of Chain Decay Input Lines,

Repeat

Repeat for number of chain decay lines

Parent Solute Name, Progeny Solute Name, Chain Decay Fraction
Warning

This option requires the Radioactive Decay Module to be implemented in the simulator.\

First-Order Reactions
Repeat

Repeat for number of solutes

Solute Name,Power, Continuous, Number of Reactions, ...

Repeat

Repeat for number of reactions

...First-order Reaction Rate Constant, Units(s),

Number of Reaction Input Lines,

Repeat

Repeat for number of reaction lines

Parent Solute Name, Daughter Solute Name, Reaction Number, Reaction Stoichiometry Fraction
Warning

This option requires the Reactions Module to be implemented in the simulator.

Noncontinuous
Choose One

Choose one reaction option

No Reaction
Repeat

Repeat for number of solutes

Solute Name, Power, Noncontinuous,

Radioactive Decay
Choose One

Choose one based on option selected in Solution Control Card

Aqueous-Only Courant Number Control
Repeat

Repeat for number of solutes

Solute Name, Power, Noncontinuous, Half-life, Units(s), Aqueous-Phase Cutoff Concentration, Units(1/L3),

Number of Chain Decay Input Lines,

Repeat

Repeat for number of chain decay lines

Parent Solute Name, Progeny Solute Name, Chain Decay Fraction
All Other Options
Repeat

Repeat for number of solutes

Solute Name, Power, Noncontinuous, Half-life, Units(s),

Number of Chain Decay Input Lines,

Repeat

Repeat for number of decay lines

Parent Solute Name, Progeny Solute Name, Chain Decay Fraction
Warning

This option requires the Radioactive Decay Module to be implemented in the simulator.

First-Order Reactions
Repeat

Repeat for number of solutes

Solute Name, Power, Noncontinuous, Number of Reactions, ...

Repeat

Repeat for number of reactions

...First-order Reaction Rate Constant, Units(s),

Number of Reaction Input Lines,

Repeat

Repeat for number of reaction lines

Parent Solute Name, Daughter Solute Name, Reaction Number, Reaction Stoichiometry Fraction
Warning

This option requires the Reactions Module to be implemented in the simulator.

STOMP User Guide Home

Modules