STOMP

Output Control Card Syntax (EOR)

Input Data Types

Character string (e.g., van Genuchten, porosity, m^3/s, Roe Superbee)

Integer (no alpha characters, special characters, or punctuation) (e.g., 1, 32, 195634)

Real (decimal points and exponential notation allowed) (e.g., 0, 0.0, 1.e-12, 1.E+3, 2.345)

Keyword (exact formatting required) (e.g., file, ~Solution Control Card, binary file)

Card Title (W)

~Output Control Card,

Reference Node Output (W)

Number of Reference Nodes,

Repeat

Repeat for number of reference nodes

I Index, J Index, K Index
Choose One

Choose one depending on coordinate system specified in Grid Card.

For Cylindrical Coordinate System

Reference Node Screen Output Frequency, Reference Node Output File Frequency, Output Time Units(s), Output Length Units(m), Output Degree Units(deg), Screen Significant Digits, Output File Significant Digits, Plot File Significant Digits,

For All Other Coordinate Systems

Reference Node Screen Output Frequency, Reference Node Output File Frequency, Output Time Units(s), Output Length Units(m), Screen Significant Digits, Output File Significant Digits, Plot File Significant Digits,

Number of Reference Node Variables

Repeat

Repeat for number of reference nodes variables

Choose One

Choose one depending on whether Well Number, Petroleum Component Name and/or Solute Name is required.

For Variable

Reference Node Variable Name, Units,

For Variable + Well Number

Reference Node Variable Name, Well Number, Units,

For Variable + Well Number + Petroleum Component Name

Reference Node Variable Name, Well Number, Petroleum Component Name, Units,

 For Variable + Petroleum Component Name

Reference Node Variable Name, Petroleum Component Name, Units,

For Variable + Solute Name

Reference Node Variable Name, Solute Name, Units,

Plot File Output (W)

Number of Plot File Times,

Repeat

Repeat for number of plot file times

Plot File Output Time, Units(s),  

Number of Plot File Variables

Repeat

Repeat for number of plot file variables

Choose One

Choose one depending on whether Petroleum Component Name or Solute Name is required.

For Variable

Reference Node Variable Name, Units,

For Variable + Petroleum Component Name

Reference Node Variable Name, Petroleum Component Name, Units,

For Variable + Solute Name

Reference Node Variable Name, Solute Name, Units,
Info

Restart Files

By default, a restart.n file is written with every plot.n file.

If "No restart" is specified as a plot file variable, no restart files will be written at any time.

If "Final restart" is specified as a plot file variable, the only restart file written will be at the final timestep or at the termination of a simulation.

Tip

3D grid

For cylindrical coordinate systems, STOMP writes output in a 2D X-Z plane (a slice). For output in 3 dimensions (a wedge), the user can specify 3d grid as a plot file variable.

STOMP User Guide Home

Modules