STOMP

Output Control Card Options (EOR)

Two types of output can be requested in the output control card: 1) Reference Node output and 2) Plot file output. 

Reference Node Output

Reference node output is generated by selecting reference nodes, or grid cells, and output variables. The user may request any number of reference nodes, but reference node output was primarily designed for tracking the time evolution of selected variables at key points of interest. Reference nodes are defined with three indices, which indicate the x-, y-, and z-direction coordinates of the grid cell. Grid cell numbering in the simulator increments in the order i, j, and k, where the indices refer to the x-, y-, and z-directions, respectively, for Cartesian coordinate systems, and r-, θ-, and z-directions, respectively, for cylindrical coordinate systems. Reference Node Screen Output Frequency and Reference Node Output File Frequency are parameters that indicate how often, with respect to time step reference node, output will be written to STDIO and the output file, respectively. A frequency value of 1 indicates reference node output occurs every time step, whereas a frequency value of 10 indicates that reference node output occurs every 10 time steps. The user has control over the output time and length units and the number of significant digits reported to the various output media. Unless declared through the Output Time Units or Output Length Units input items, values for time and lengths recorded to the output media will be expressed in units of seconds and meters, respectively. These inputs allow the user to customize time- and length-scale units to those most appropriate to the solved problem. The Screen Significant DigitsOutput File Significant Digits, and Plot File Significant Digits input items allow the user to customize the number of significant digits that appear in field and flux variable results written to the STDIO, output file, and plot.n file, respectively. The default value for the number of significant digits is 5, and the minimum number of significant digits is 4. The same list of variables for each operational mode is available for output to the plot.n files. Output units for all variables with units can be specified immediately following the variable name. Variables without units require a null entry for the variable units. Null entries for variables with units yield default output units, which are expressed in SI units.  Variables that can be specified for reference node output are shown in the table below.  Checks in the Well Number, Petroleum Component Name, and/or Solute Name indicate addition input is required after the variable name, delimited by a comma(s).

Reference Node Variables

Variable Name

Well Number

Petroleum Component Name

Solute Name

SI Units
aqueous concentration     kg/m3
aqueous courant number        
aqueous density       kg/m3
aqueous gauge pressure       Pa
aqueous hydraulic head       m
aqueous mass fraction      
aqueous moisture content        
aqueous pressure       Pa
aqueous relative permeability        
aqueous salt concentration       kg/m3
aqueous saturation        
aqueous viscosity       Pa s
cricondentherm temperature       C
critical temperature       C

Variable Name

Well Number

Petroleum Component Name

Solute Name

SI Units
differential integrated mass     kg
differential integrated water mass       kg
diffusive porosity        
effective trapped gas saturation        
gas concentration     kg/m3
gas courant number        
gas density       kg/m3
gas gauge pressure       Pa
gas hydraulic head       m
gas mass fraction      
gas mole fraction      
gas pressure       Pa
gas relative permeability        
gas viscosity       Pa s

Variable Name

Well Number

Petroleum Component Name

Solute Name

SI Units
injection well petroleum component mass integral   kg
injection well petroleum component mass rate   kg/s
injection well total petroleum mass integral     kg
injection well total petroleum mass rate     kg/s
injection well water mass integral     kg
injection well water mass rate     kg/s
integrated aqueous mass     kg
integrated aqueous water mass       kg
integrated energy       J
integrated gas mass     kg
integrated gas water mass       kg
integrated mass     kg
integrated water mass       kg

Variable Name

Well Number

Petroleum Component Name

Solute Name

SI Units
mass source integral     kg
mass source rate     kg/s
node number        
nonaqueous liquid concentration     kg/m3
nonaqueous liquid density       kg/m3
nonaqueous liquid guage pressure       Pa
nonaqueous liquid mass fraction      
nonaqueous liquid mole fraction      
nonaqueous liquid pressure       Pa
nonaqueous liquid relative permeability,        
nonaqueous liquid saturation        
nonaqueous liquid viscosity       Pa s

Variable Name

Well Number

Petroleum Component Name

Solute Name

SI Units
phase condition        
production well fluid density     kg/m3
production well petroleum component mass integral   kg
production well petroleum component mass rate   kg/s
production well total petroleum mass integral     kg
production well total petroleum mass rate     kg/s
production well water mass integral     kg
production well water mass rate     kg/s
rock/soil type        
salt aqueous mass fraction        
salt mass source integral       kg
salt mass source rate       kg/s
salt mole fraction        
salt saturation        

Variable Name

Well Number

Petroleum Component Name

Solute Name

SI Units
solute aqueous concentration     sol/m3
solute aqueous mole fraction      
solute gas concentration     sol/m3
solute gas mole fraction      
solute nonaqueous liquid concentration     sol/m3
solute nonaqueous liquid mole fraction      
solute source rate     sol/s
solute volumetric concentration     sol/m3
system pressure       Pa
temperature       C
total component mole fraction      
total salt mass       kg
total water mass       kg
vapor pressure     Pa
volumetric salt concentration       kg/m3

Variable Name

Well Number

Petroleum Component Name

Solute Name

SI Units
water aqueous concentration       kg/m3
water aqueous mass fraction        
water gas concentration       kg/m3
water gas mass fraction        
water gas mole fraction        
water mass source integral       kg
water mass source rate       kg/s
water vapor pressure       Pa
well injection pressure     Pa

Variable Name

Well Number

Petroleum Component Name

Solute Name

SI Units
x aqueous volumetric flux       m/s
x gas volumetric flux       m/s
x heat flux       W/m2
x intrinsic permeability       m2
x node centroid       m
x salt flux       kg/s m2
x solute flux     sol/s m2
xnc aqueous volumetric flux       m/s
xnc gas volumetric flux       m/s
xnc heat flux       W/m2
xnc salt flux       kg/s m2

Variable Name

Well Number

Petroleum Component Name

Solute Name

SI Units
y aqueous volumetric flux       m/s
y gas volumetric flux       m/s
y heat flux       W/m2
y intrinsic permeability       m2
y node centroid       m
y salt flux       kg/s m2
y solute flux     sol/s m2
ync aqueous volumetric flux       m/s
ync gas volumetric flux       m/s
ync heat flux       W/m2
ync salt flux       kg/s m2
y solute flux     sol/s m2

Variable Name

Well Number

Petroleum Component Name

Solute Name

SI Units
z aqueous volumetric flux       m/s
z gas volumetric flux       m/s
z heat flux       W/m2
z intrinsic permeability       m2
z node centroid       m
z salt flux       kg/s m2
z solute flux     sol/s m2
znc aqueous volumetric       m/s
znc gas volumetric       m/s
znc heat flux       W/m2
znc salt flux       kg/s m2

Plot File Output

Plot files are written at the conclusion of an execution, by default, and at each requested Plot File Output Time. Plot files contain geometry data and selected field and flux variable results for every node in the computational domain. These files represent a “snapshot” of the simulation at a certain point in time. Requests for Plot File Output Times can be specified with user defined units. A restart.n file is generated with every plot.n file. Both restart.n and plot.n files are suffixed with a file name extension of a dot followed by an integer (e.g., plot.567, restart.0032). The extension integer corresponds with the time step for which the file was written. Both plot.n and restart.n files are written at the conclusion of a time step. Field and flux variables recorded to plot.n files are selected from the list shown below. Output units for all variables with units can be specified in the input item immediately following the variable name. Variables without units require a null entry for the variable units. Null entries for variables with units yield default output units, which are expressed in SI units. Checks in the Petroleum Component Name or Solute Name indicate addition input is required after the variable name, delimited by a comma(s).

 

For Reactive Transport modules, this card has been modified to allow for reactive species output to the output and plot.n files. Reactive species output in Reference Node or Plot File forms is specified in the same manner as solute output, with the exception that the keyword Species is used instead of Solute. Required input includes the output variable, species name, and output units.

Plot File Variables

Variable Name

Petroleum Component Name

Solute Name

SI Units
apparent aqueous saturation      
aqueous concentration   kg/m3 
aqueous courant number      
aqueous density     kg/m3
aqueous gauge pressure     Pa
aqueous hydraulic head    
aqueous mass fraction    
aqueous moisture content      
aqueous mole fraction    
aqueous pressure     Pa
aqueous relative permeability      
aqueous salt concentration     kg/m3
aqueous saturation      
aqueous viscosity     Pa s
cricondentherm temperature     C
critical temperature     C

Variable Name

Petroleum Component Name

Solute Name

SI Units
diffusive porosity      
effective trapped gas saturation      
final restart      
gas concentration   kg/m3
gas courant number      
gas density     kg/m3
gas gauge pressure     Pa
gas hydraulic head     m
gas mass fraction    
gas mole fraction    
gas pressure     Pa
gas relative permeability      
gas saturation      
gas viscosity     Pa s

Variable Name

Petroleum Component Name

Solute Name

SI Units
mass source integral   kg
mass source rate   kg/s
no restart      
node number      
nonaqeuous liquid saturation      
nonaqueous liquid concentration   kg/m3
nonaqueous liquid density     kg/m3
nonaqueous liquid gauge pressure     Pa
nonaqueous liquid mass fraction    
nonaqueous liquid mole fraction    
nonaqueous liquid pressure     Pa
nonaqueous liquid relative permeability      
nonaqueous liquid viscosity     Pa s

Variable Name

Petroleum Component Name

Solute Name

SI Units
phase condition      
rock/soil type      
salt aqueous mass fraction      
salt aqueous mole fraction      
salt mass source rate     kg/s
salt saturation      
solute aqueous concentration   sol/m2
solute gas concentration   kg/m3
solute nonaqueous liquid concentration   kg/m3
solute source rate   kg/s
solute volumetric concentration   kg/m3
system pressure     Pa
total component mole fraction    
total mass   kg
total salt mass     kg
total water mass     kg

Variable Name

Petroleum Component Name

Solute Name

SI Units
vapor pressure   Pa
volumetric salt concentration     kg/m3
water aqueous concentration     kg/m3
water aqueous mass fraction      
water gas concentration     kg/m3
water gas mass fraction      
water gas mole fraction      
water mass source integral     kg
water mass source rate     kg/s
water vapor pressure     Pa

Variable Name

Petroleum Component Name

Solute Name

SI Units
x aqueous volumetric flux     m/s
x gas volumetric flux     m/s
x heat flux     W/m2
x intrinsic permeability     m2
x node centroid     m
x salt flux     kg/s m2
x solute flux   sol/s m2
xnc aqueous volumetric flux     m/s
xnc gas volumetric flux     m/s
xnc heat flux     W/m2
xnc salt flux     kg/s m2

Variable Name

Petroleum Component Name

Solute Name

SI Units
y aqueous volumetric flux     m/s
y gas volumetric flux     m/s
y heat flux     W/m2
y intrinsic permeability     m2
y node centroid     m
y salt flux     kg/s m2
y solute flux   sol/s m2
ync aqueous volumetric flux     m/s
ync gas volumetric flux     m/s
ync heat flux     W/m2
ync salt flux     Pa

Variable Name

Petroleum Component Name

Solute Name

SI Units
z aqueous volumetric flux     m/s
z gas volumetric flux     m/s
z heat flux     W/m2
z intrinsic permeability     m2
z node centroid     m
z salt flux     kg/s m2
z solute flux   sol/s m2
znc aqueous volumetric flux     m/s
znc gas volumetric flux     m/s
znc heat flux     W/m2
znc salt flux     kg/s m2

 

 

STOMP User Guide Home

Modules